Business management · Metrology and Calibration

An instrument that measures wrong rejects good lots and approves bad ones

An uncalibrated caliper, a retouching monitor out of profile, a scale that reads high. The Metrology module controls the whole instrument: range, resolution, maximum permissible error, point-by-point calibration with uncertainty, the certificate on file, a traceable reference standard, checkout and loan, and repeatability and reproducibility studies. Most important of all, a blocked instrument is refused at the moment of measurement, not discovered during an audit.

The problem and the fix

The problems Metrology and Calibration solves every day

If any of these situations sounds familiar, it is because they happen in almost every graduation company, until the right system comes in.

The problem

The calibration spreadsheet exists, but nobody looks at it, and the overdue instrument keeps measuring on the production floor.

With Partiu Formatura

Status recalculated every day, an alert before the due date and a usage hold: the overdue instrument is refused at inspection and at production reporting, with the reason on the screen of whoever was about to measure.

The problem

The laboratory wrote pass on the certificate, and nobody checked whether the error fits the part tolerance.

With Partiu Formatura

Maximum permissible error registered on the instrument and calibration recorded point by point. A point outside the limit fails the calibration even when the certificate says pass, and opens a nonconformity on its own.

The problem

The certificate is in a drawer, nobody knows which standard was used, and the audit asks for the traceability chain.

With Partiu Formatura

Certificate attached to the record, reference standard registered with its own certificate and a link showing which standard was used in which calibration. The chain opens in one click.

The problem

The instrument is gone, somebody took it to the event and nobody knows who has it.

With Partiu Formatura

Checkout and return recorded with the person responsible, location and expected return date. A loaned instrument does not show as available to anyone else, and an overdue return takes it off everyone's list.

The problem

Two operators measure the same part and get different results, and the discussion turns into opinion.

With Partiu Formatura

MSA study with repeatability and reproducibility calculated by average and range and by ANOVA, with the decision recorded: above 30 percent fails, between 10 and 30 requires justification.

In practice

Real examples of Metrology and Calibration working for you

Everyday situations at graduation companies, from the problem to the result, using the modules on this page.

01

A retouching monitor out of profile

The scenario

The studio delivers an entire batch with a color cast, and the retouching was approved on the monitor that was wrong.

With the system

The monitor is registered as an instrument with a profiling interval, the hold switched on and an owner. Once it expires, the visual color inspection refuses to use it.

The result

The defect stops being created, and the cost of poor quality for that batch ceases to exist.

02

A caliper that fails its annual calibration

The scenario

The laboratory returns the instrument with deviation above the acceptable limit at two of the five points.

With the system

The points are entered with reading and uncertainty. The system fails it, does not push the expiry date forward, puts the instrument into maintenance and opens the nonconformity.

The result

The measurements taken with it stay traceable through the inspection, and the decision on what to do with the product is made with data, not from memory.

03

A certification audit asking for traceability

The scenario

The auditor picks an instrument and asks for the chain up to the national standard.

With the system

The record shows the calibration, the attached certificate, the accredited laboratory with its accreditation number and validity, and the reference standard used along with its own certificate.

The result

The evidence comes out on the spot, with no folder to hunt for and no call to the laboratory.

How it works

How information flows through Metrology and Calibration

Every step is a real module, and what comes out of one goes into the next without anyone typing it again.

  1. 1RegistrationThe instrument is registered with range, resolution, maximum permissible error, interval and criticality.
  2. 2CalibrationThe calibration is recorded point by point, with the laboratory, the certificate and the standards used.
  3. 3DecisionThe system calculates point by point and decides. A failure opens a nonconformity and keeps the instrument out of use.
  4. 4UseAt inspection and at production reporting, whoever is about to measure picks the instrument. A blocked one is refused with the reason.
  5. 5SurveillanceThe daily job flags calibration, standard and accreditation expiries, plus overdue returns.

Module by module

Everything included in Metrology and Calibration

7 modules and 38 features on this page, all running on the same class, graduate and event records.

Instrument Record

What it measures, over what range and with how much error still acceptable.

  • Code, name, type, manufacturer, model, serial number, asset tag and owner
  • Unit, measuring range, resolution and maximum permissible error
  • A, B or C criticality: A is the instrument that measures what rejects product
  • Decision rule per instrument: with uncertainty or simple error
  • Default laboratory pulled from the supplier register
  • Location, status and full history on the same screen

Calibration With a Criterion

The result comes from the calculation, and the calculation is kept.

  • Calibration points with nominal value, reading, expanded uncertainty and coverage factor k
  • Error calculated per point and compared against the point limit or the instrument limit
  • Calculated result and reported result stored side by side
  • A point outside the limit fails, even when the laboratory reports a pass
  • A failure does not push the expiry date forward and opens a nonconformity automatically
  • Rule and limit frozen into the record: changing the instrument later does not rewrite the past

Certificates and Laboratories

The document that proves it, attached where people look for it.

  • Certificate in PDF, PNG or JPG attached to the calibration
  • Laboratory picked from the supplier register, with no free-typed names
  • RBC (Brazilian calibration network) accreditation with number and validity, required when the laboratory is accredited
  • Accreditation expired on the calibration date blocks the record
  • An alert when the accreditation of the instrument's laboratory is about to expire
  • Number, file and submission date kept together

Reference Standards

The chain that links your measurement to the national standard.

  • Standard registered with its own certificate, validity and uncertainty
  • A link showing which standards were used in each in-house calibration
  • A standard expired on that date blocks the calibration that tried to use it
  • Reverse traceability: which instruments depend on this standard
  • Alerts for expired and soon-to-expire standards in the daily job

Checkout and Location

Where it is and who has it, without relying on memory.

  • Checkout with owner, location, purpose and expected return date
  • Return with condition checked: damage blocks the instrument immediately
  • A loaned instrument drops off the list for anyone who is not the holder
  • An overdue return takes the instrument off everyone's list
  • Daily alert for overdue returns

MSA, Repeatability and Reproducibility

The measurement system gets measured too.

  • A study with parts, operators and trials, with every reading stored one by one
  • Calculation by average and range and by analysis of variance, side by side
  • Percentage of total variation and of tolerance, plus the number of distinct categories
  • Above 30 percent fails and opens a nonconformity
  • Between 10 and 30 percent requires a recorded justification from whoever approved it

A Hold That Holds on the Floor

The rule that makes the module worth having.

  • An instrument that is overdue, never calibrated, under maintenance, inactive or manually blocked is refused
  • Manual hold with reason, author and date, released only by someone with permission
  • An inspection criterion can require the instrument to be named in the measurement answer
  • The production reporting terminal refuses a blocked instrument and shows the reason
  • Monthly calibration calendar and a dashboard of overdue, due soon and blocked instruments

Find the right plan for Metrology and Calibration

Compare the modules and choose the setup that fits your operation.